Fire Sprinkler Testing Checklist

Testing and maintenance of water based fire protection systems.
Fire sprinkler testing checklist. Table 5 1 1 2 summary of sprinkler system inspection testing and maintenance item frequency reference inspection control valves chapter 13 fire department connections chapter 13. Maintenance and testing of fire sprinkler systems. Fire sprinkler system. In table 5 1 1 2 correct the cross references to read as follows.
Life safety code section 9 75 2000 edition. 2 3 2009 8 15 00 pm company. Regular testing is also required statewide through the illinois office of the state fire marshal s adoption of nfpa 101. 20 or fewer sprinklers shall not require testing in.
Fire sprinkler inspection checklist it s vital to schedule a fire sprinkler inspection on a quarterly semi annual or annual basis to confirm your system is up to code and working properly. Introduction when properly installed and maintained automatic fire sprinkler systems have proven to be the most effective means for protecting life and property against fire. If your sprinkler system is hydraulic inspect the hydraulic nameplate to make sure it is attached and visible. Quarterly inspection checklist.
The quarterly inspection includes everything that is required for a monthly inspection 1 2 plus some additional items 3 7. Michael richard gammell last modified by. Wet sprinkler system a modifications affecting more than 20 sprinklers will require testing. Unless done by a qualified fire sprinkler company an inspection does not normally include testing disassembling or removing any sprinkler equipment or component.
The national fire protection association nfpa sets the standards for fire protection systems and measures in commercial buildings. The following is a list of what should be checked during the quarterly and annual inspections for a typical wet or dry pipe fire sprinkler system. Sprinkler pre inspection checklist 2007 nfpa 13 updated. These inspections must be conducted by a fire safety professional who is certified and knowledgeable on the subject matter.
All automatic fire sprinkler systems standpipe systems and fire pumps. Inspection and testing form author. Standard for the inspection testing and maintenance of water based fire protection systems. The following procedures shall be performed at each required quarterly inspection of a fire sprinkler system.
06 2008 q system valves and gauges shall be accessible for operation inspection tests and maintenance 13 8 1 2 2.